Abstract

Simulation tests of a BWR loss-of-coolant accident (LOCA) by a postulated full size, double-ended break of a recirculation suction line were conducted using the Two Bundle Loop (TBL) with two full size, electrically heated bundles. In the tests, single failure of emergency core cooling systems (ECCSs) was assumed. The following results were obtained from the tests: (1) The rods heated up early in one of the two bundles, while heatup initiations were delayed in the other. The difference was observed for any ECCS activation mode. (2) The peak cladding temperature (PCT) of each bundle was expressed as a linear function of integrated power during the heatup period. (3) The highest PCT in the tests was 861 K under the assumption of an HPCS (high pressure core spray) failure, which was well below the licensing limitation of 1,473 K.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.