A diagnostic tool for bridging faults combining three different data sources is presented. The first data source is a set of IDDQ measurements used to identify the most probable fault type. The second source is a list of parasitic capacitances extracted from layout and used to create a list of realistic potential bridging fault sites. The third source is logical faults detected at the primary outputs (including scan flip flops), used to limit the number of suspected gates. The combination of these data significantly reduces the number of potential fault sites to consider in the diagnosis process. Simulation results confirm that the number of potential bridging fault sites is reduced from O(N2) to less than O(N), where N is the number of nodes in the circuit. The tool therefore converges quickly towards the solution while using less resources. A new technique is also introduced to estimate the additional delay caused by the diagnosed bridging fault based on the diagnostic results. Performing this estimation allows us to confirm the previous diagnosis results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.