This paper introduces a new, cost-effective and compact DGS ring resonator for breast cancer detection, it was designed and fabricated with a size of 15 mm × 15 mm, it was fabricated on a Roger 4003 substrate, a model of a breast with 10 mm × 10 mm × 3 mm tumor was created using CST Microwave studio, the detection process depends on the essentials of electrical material properties that the existence of tumor lead to shifting in resonant frequency. From the simulation results shifting in resonant frequency used for constructing a 29×29 matrix with 841 pixels, this matrix converted to a 2D image for the breast with tumor tissue, this 2D image identifies clearly the existence of the tumor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.