Abstract

Hydroxyapatite cement (BoneSource®) and brushite calcium phosphate cement (chronOS™ Inject) were tested for fixation of glass ceramic implants (Bioverit®) in experimentally created cranial defects in 24 adult New Zealand White rabbits. Aim of the in vivo study was to assess and compare the biocompatibility and osseointegration of the implanted materials. Macroscopic and histological evaluations were performed 1 month, 3 months, and 6 months postoperatively. All implanted materials were well tolerated by the surrounding tissue. Both bone cements exhibited osteoconductive properties. Differences could be detected regarding to the rates of cement resorption and new bone formation. The brushite cement was resorbed faster than the hydroxyapatite cement. The chronOS™ Inject samples exhibited a higher rate of connective tissue formation and an insufficient osseointegration. BoneSource® was replaced by bone with minimal invasion of connective tissue. New bone formation occurred faster compared to the chronOS™ Inject group. Bioverit® implants fixed with BoneSource® were successfully osseointegrated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.