Abstract
Abstract The paper describes in detail the operation of the boiler plant of the Colfax Station of the Duquesne Light Co., located at Cheswick, Pa. There are included sample analyses of fuel and ash, the piping schedule, temperature and CO2 records, typical water analyses, observations of dissolved oxygen in boiler feedwater, boiler-test data and a typical heat balance covering four months.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Transactions of the American Society of Mechanical Engineers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.