In general, existing machine learning based approaches, developed for systolic and diastolic blood pressure (SBP and DBP) estimation from oscillometric waveforms (OWs), employ features extracted from the OW envelope (OWE) alone and ignore important beat-by-beat (BBB) features which represent fundamental physical properties of the entire non-invasive blood pressure (NIBP) measurement system. Unlike the existing literature, this paper proposes a novel deep-learning based method for BP estimation trained with BBB time-domain features extracted from OWs. First, we extract six time-domain features from each beat of the OW, relative to the preceding beat. Second, using the extracted BBB features along with the corresponding cuff pressures, we form a feature vector for each OW beat and locate it in one of three different classes, namely pre-systolic (PS), between systolic and diastolic (BSD) and after diastolic (AD). We then devise a deep-belief network (DBN)-deep neural network (DNN) classification model as well as a novel artificial feature extraction method for estimating SBP and DBP from feature vectors extracted from OWs and their corresponding deflation curves. The proposed DBN-DNN classification approach can effectively learn the complex nonlinear relationship between the artificial feature vectors and target classes. The SBP and DBP points are then obtained by mapping the beats at which the network output sequence switches from PS phase to BSD phase and from BSD phase to AD phase, respectively, to the deflation curve. Adopting a 5-fold cross-validation scheme and using a data base of 350 NIBP recordings gave an average mean absolute error of 1.1±2.9 mmHg for SBP and 3.0±5.6 mmHg for DBP relative to reference values. We experimentally show that the proposed DBN-DNN-based classification algorithm trained with BBB time-domain features can outperform traditional deep-learning based methods for BP estimation trained with features extracted only from OWEs.

Highlights

  • Automated non-invasive blood pressure (NIPB) measurement is widely used to estimate SBP and DBP

  • We experimentally show that the proposed deep-belief network (DBN)-deep neural network (DNN)-based classification algorithm trained with BBB time-domain features can outperform traditional deep-learning based methods for BP estimation trained with features extracted only from oscillometric waveform envelope (OWE)

  • We assumed a DBN-DNN with 3 hidden layers each of which included 50 hidden units trained with the derived artificial features from the proposed BBB features

Read more

Summary

Introduction

Automated non-invasive blood pressure (NIPB) measurement is widely used to estimate SBP and DBP. While NIBP monitors available on the market may estimate BP by both auscultatory and oscillometric techniques, the majority of them today are based on the oscillometric method [1]–[4] because of its simplicity and robustness. The oscillometric method requires the inflation of the cuff beyond the. The associate editor coordinating the review of this manuscript and approving it for publication was Bo Jin. anticipated systolic pressure. The oscillometric waves (OWs) superimposed on the pressure measurement are processed to produce the oscillometric waveform envelope (OWE).

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.