Abstract

This study aimed to determine the effect of the thickness of the sand filter and the best residence time for water purification. The type of sand used in this study was concrete sand, and the observation was focused on turbidity (NTU) parameter. Measurements of turbidity were performed before treatment, as well as at each retention time from 1 to 9 days. The method of data analysis was Linear Regression analysis on SPSS 21 program. Blackwater was collected in the morning and afternoon, and the turbidity of each sample was 1000 and 800 NTU, respectively. Wastewater turbidity was continued to decreased along with the longer retention time. The best results were obtained from the treatment 3 (sand filter 20 cm) with 9 days retention time, in which the turbidity levels decreased to 90 NTU (morning sample), and 105 NTU (afternoon sample).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.