Abstract

In this study, heat transfer and cost optimization of a gas-to-gas heat exchanger (recuperator) operating in the targeted temperature range has been made. Firstly, the thermophysical properties of the waste heat source and the volumetric flow rates of the flows were obtained, and the maximum heat that could be recovered was obtained. Afterward, a parametric study was carried out to size the recuperator. The parameters affecting the cost, such as hot flow and cold flow outlet temperatures, were determined by the overall heat transfer coefficient, effectiveness, and pressure drop. Finally, the thermal parameters obtained from the parametric study are used in the technoeconomic analysis. The recuperator geometry with the maximum saving coefficient was determined considering investment and operating costs. As a result, the 108th simulation resulted in maximum savings with 653 252 $/year using 321.19 m2 heat transfer surface area.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.