Abstract

AbstractProcess condensate wastewaters from two fixed‐bed gasifiers have been treated successfully using a laboratory‐scale, fixed‐film, fluidized‐bed bioreactor. Both dilute (1 to 2% raw wastewater) and more concentrated (50% stripped wastewater) were treated continuously for periods of one to three months. Biological activity was stable, recovery from upsets was rapid, and reaction rates were high due to the high concentration of microorganisms retained on the support particles. Removal of phenolics exceeded 99%, and removal of chemical oxygen demand was typically 75 to 85% for the 50% stripped wastewater with a hydraulic residence time in the bed of ˜5 to 7 h. Sludge production rates were comparable to rates in suspended growth systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.