ObjectiveTo investigate the biomechanical effects of percutaneous vertebroplasty combined with cement pedicle plasty (PVCPP) on the unstable osteoporotic vertebral fractures (OVFs) through finite element (FE) analysis. The study compares the biomechanical stability of finite element models between percutaneous vertebroplasty (PVP) and percutaneous vertebroplasty combined with cement pedicle plasty.MethodsTwo patients with unstable OVFs underwent computed tomography (CT) examination at the thoracolumbar vertebral body levels, respectively. The CT images were reconstructed into three-dimensional finite element models to simulate stress conditions across six dimensions and to evaluate the vertebral von Mises stress before and after bone cement reinforcement.ResultsThe study found that stress distribution differed between groups mainly at the pedicle base. In the surgical vertebral bodies, the maximum stress in the PVP group decreased during flexion and left bending, while it increased in other states. In the PVCPP group, all maximum stresses decreased. In the inferior vertebral bodies, the maximum stress in the PVP group generally increased, while it decreased in the PVCPP group. In the superior vertebral bodies, postoperatively, the maximum stress in the PVP group generally increased, while it almost remained unchanged in the PVCPP group. PVP group had higher cement stress and displacement.ConclusionPVCPP is an effective treatment method for patients with unstable OVFs. It can quickly relieve pain and enhance the stability of the three columns, thereby reducing the risk of some complications.