Abstract

Background ContextThere have been conflicting results on the surgical outcome of lumbar fusion surgery using two different techniques: robot-assisted pedicle screw fixation and conventional freehand technique. In addition, there have been no studies about the biomechanical issues between both techniques. PurposeThis study aimed to investigate the biomechanical properties in terms of stress at adjacent segments using robot-assisted pedicle screw insertion technique (robot-assisted, minimally invasive posterior lumbar interbody fusion, Rom-PLIF) and freehand technique (conventional, freehand, open approach, posterior lumbar interbody fusion, Cop-PLIF) for instrumented lumbar fusion surgery. Study DesignThis is an additional post-hoc analysis for patient-specific finite element (FE) model. Patient SampleThe sample is composed of patients with degenerative lumbar disease. Outcome MeasuresIntradiscal pressure and facet contact force are the outcome measures. MethodsPatients were randomly assigned to undergo an instrumented PLIF procedure using a Rom-PLIF (37 patients) or a Cop-PLIF (41), respectively. Five patients in each group were selected using a simple random sampling method after operation, and 10 preoperative and postoperative lumbar spines were modeled from preoperative high-resolution computed tomography of 10 patients using the same method for a validated lumbar spine model. Under four pure moments of 7.5 Nm, the changes in intradiscal pressure and facet joint contact force at the proximal adjacent segment following fusion surgery were analyzed and compared with preoperative states. ResultsThe representativeness of random samples was verified. Both groups showed significant increases in postoperative intradiscal pressure at the proximal adjacent segment under four moments, compared with the preoperative state. The Cop-PLIF models demonstrated significantly higher percent increments of intradiscal pressure at proximal adjacent segments under extension, lateral bending, and torsion moments than the Rom-PLIF models (p=.032, p=.008, and p=.016, respectively). Furthermore, the percent increment of facet contact force was significantly higher in the Cop-PLIF models under extension and torsion moments than in the Rom-PLIF models (p=.016 under both extension and torsion moments). ConclusionsThe present study showed the clinical application of subject-specific FE analysis in the spine. Even though there was biomechanical superiority of the robot-assisted insertions in terms of alleviation of stress increments at adjacent segments after fusion, cautious interpretation is needed because of the small sample size.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call