Abstract
The biological variation of anti-TPO and anti-Tg autoantibodies was studied in 17 clinically and biochemically stable female patients with autoimmune thyroid disease (AITD), at regular monthly intervals over a period of 6 consecutive months. The mean and standard deviation (SD), within-subject coefficient of variation (CV), between-subject CV, index of individuality, reliability coefficient, and critical differences were as follows: for anti-TPO 238 (197) U/ml, 9.2%, 81.4%, 0.11, 0.96, and 27.6%; and for anti-Tg 1,785 (3,170) U/ml, 6.9%, 174%, 0.04, 0.99, and 22.3%. The data indicate a low within-subject CV, and a high between-subject CV that is particularly pronounced for anti-Tg. The high individuality of both autoantibodies indicates that an isolated result compared to conventional population-based reference intervals is of very little value for diagnosis. Furthermore, the near to 1 reliability coefficient for both autoantibodies correctly classifies the patient with respect to his or her homeostatic mean antibody concentration in a 6-month period of clinical and biochemical stability of thyroid disease. Imprecision goals for anti-TPO and anti-Tg antibodies are attainable with current methodology.
Published Version (