Abstract
Head space gas chromatography (GC) was applied to measure methyl ethyl ketone (MEK) in urine from 62 MEK-exposed male workers, whose individual intensity of exposure to MEK was monitored utilizing the carbon felt dosimeter. The urinary MEK level increased rapidly to reach a plateau in the first quarter of the daily 8-h work, while very little MEK was detected in the preshift urine. When the MEK levels in the urine at the end of the shift were compared with the afternoon MEK-TWA values, the uncorrected MEK in urine correlated best with MEK in air (r = 0.774, n = 62), while correction for creatinine gave a comparable result and the correlation was poorer when corrected for a specific gravity of urine or for the lapse of time after preceding passage of urine. Balance of MEK absorption via inhalation and MEK excretion into urine revealed that only 0.1% of MEK absorbed will be excreted unchanged into urine. Wider application of head space GC is discussed for the analysis of unmetabolized solvents in urine.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International archives of occupational and environmental health
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.