Abstract
To study the RBE of 15 MeV neutrons for normal tissues, the responses of jejunal crypt cells, lung, and esophagus to 15 MeV neutrons generated from a deuterium-tritium neutron generator were compared with responses to 137Cs (cesium) γ- or 300 kVp X-rays in the mouse. For jejunal crypt cell survival, the RBE was 1.5 at a survival of 10 crypt cells per circumference. The RBE for pulmonary lethal dose LD 50 160 and esophageal LD 50 28 was 1.2 and 3.02, respectively. Data available in the literature on the effects of 15 MeV neutrons on tumor and normal tissues were reviewed; additional studies which should be performed prior to the clinical use of 15 MeV deuterium-tritium neutron generators are suggested.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Radiation Oncology, Biology, Physics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.