Abstract

The biodegradation of phenol, p-cresol, and phenol plus p-cresol mixtures was evaluated using Pseudomonas putida ATCC 17484 in aerobic batch reactors. Shake-flask experiments were performed separately using growth medium with initial nominal concentrations of phenol (50–600 mg L−1) and p-cresol (50–600 mg L−1) as well as phenol (50–600 mg L−1) plus p-cresol (50–600 mg L−1). The complete degradation of phenol and p-cresol was achieved within 48 h and 48–56 h, respectively, for all initial concentrations of phenol and p-cresol. The maximum cell growth rate using phenol (μmax,P = 0.45 h−1) was much faster than that using p-cresol (μmax,C = 0.185−1 h). The larger Ki value for phenol (310.5 mg L−1) revealed that the P. putida cells had a higher resistance to phenol inhibition compared with p-cresol (243.56 mg L−1). A mixture of phenol and p-cresol in batch experiments resulted in the complete removal of phenol within 52–56 h for initial phenol concentrations of 50–500 mg L−1. The time needed to remove p-cresol completely was 48–56 h for initial p-cresol concentrations of 50–500 mg L−1. In the continuous-flow immobilized cells reactor, the degradation efficiency for phenol and p-cresol was 97.6 and 89.1%, respectively, at a stable condition.

Highlights

  • IntroductionPhenol and its derivatives are toxic organic components often found in various petroleum and chemical industries [1]

  • The biodegradation p-crewas validated by conducting a continuous stirred-tank bioreactor with immobilized cells in sol was validated by conducting a continuous stirred-tank bioreactor with immobilized

  • Model agreed with experimental data very data well very in thewell continuoussidered in the modelThe system

Read more

Summary

Introduction

Phenol and its derivatives are toxic organic components often found in various petroleum and chemical industries [1]. Phenol has been regarded as a toxic pollutant to aquatic living organisms imparted as low as concentrations of 0.005 mg L−1 [2]. There has been serious environmental concern due to the persistent toxicity of phenol and its derivatives [3]. Much industrial wastewater contains the major phenol and its derivatives such as phenol and cresols [4,5]. The removal of these phenolic contaminants to a satisfactorily low level in wastewater becomes an urgent task

Objectives
Methods
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.