Abstract
This study presents the removal of phenol by heterogenous photo electro Fenton-like (PEF-like) system using nano-zero valent iron (NZVI). NZVI was characterized using X-ray diffraction (XRD) and Scanning Electron Microscope (SEM) analysis. The effect of initial pH, initial concentration of phenol, NZVI dosage and initial H2O2 concentration on phenol removal was studied. The removal efficiency was increased with an increase in NZVI dosage and decreased with an increase in initial phenol concentration and initial pH. The optimum dosage of NZVI and H2O2 were found to be 0.5g/L and 500mg/L, respectively and complete removal of phenol was observed within 30min at these conditions at an initial pH and initial phenol concentration of 6.2 and 200mg/L, respectively. The analysis of kinetics showed that the removal of phenol by PEF-like process followed pseudo first-order kinetics. The variation of H2O2 concentration during the reaction was monitored at different current densities and the optimum current density was found to be 12mA/cm2.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.