Abstract

In order to treat antibiotic wastewater with high efficiency and low energy consumption, this study proposed the coupling of electrocatalytic degradation and biodegradation, and explored a new modified electrocatalytic material in the coupling system. The stainless-steel mesh based molybdenum carbide (SS-Mo2C) was prepared by a low-cost impregnation method and showed superior electrocatalytic degradation ability for tetracycline (TC) when used as the anode in the electrocatalytic system. The degradation rate of TC with SS-Mo2C anode was 17 times higher than that of stainless-steel (SS) anode, and TC removal efficiency was 77% higher than that of SS anode. The electrocatalytic system prior to the biological reactor was proven to be the optimal coupling method. The external coupling system achieved a significantly higher TC removal (87.0%) than that of the internal coupling system (65.3%) and SS-Mo2C showed an excellent repeatable and stable performance. The fewer and smaller molecular weight intermediates products were observed in bio-electrocatalytic system, especially in the external coupling system. Alpha diversity analysis further confirmed that bio-electrocatalytic system increased the diversity of the microbial community. The stainless-steel mesh based molybdenum carbide (SS-Mo2C), which was prepared by a simple and low-cost impregnation method, significantly improved the electrocatalytic activity of anode, thus contributing to tetracycline removal in the bio-electrocatalytic system, especially in the external coupling system.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call