Abstract
We present the case of a 3-month-old boy who suffered bilateral pneumothoraces secondary to insufflation of oxygen into the endotracheal tube during the apnea test as part of brain death testing. Although rare, awareness of this potential complication of the apnea test is of particular importance in pediatric patients who have narrow endotracheal tubes because resistance to expiratory flow increases exponentially as lumen diameter decreases.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.