Abstract

Apnea testing is a key component in the clinical diagnosis of brain death. Patients with poor baseline oxygenation may not tolerate the standard 8-10 min apnea testing with oxygen insufflation through tracheal tube. No studies have assessed the safety and feasibility of other methods of oxygenation during apnea testing in these types of patients. Here, we safely performed apnea testing in a patient with baseline PaO2 of 99.1 mm Hg at 100% oxygen. We used continuous positive airway pressure (CPAP) of 10 cm of H2O and 100% oxygen at the flow rate of 12 L/min using the circle system of anesthesia machine. After 10 min of apnea testing, PaO2 decreased to 75.7 mm Hg. There was a significant rise in PaCO2 and fall in pH, but without hemodynamic instability, arrhythmias, or desaturation. Thus, the apnea test was declared positive. CPAP can be a valuable, feasible and safe means of oxygenation during apnea testing in patients with poor baseline oxygenation, thus avoiding the need for ancillary tests.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.