Abstract

Cu-ion-migration-induced dielectric breakdown in damascene Cu interconnect was studied in alternating polarity-bias conditions using a metal–insulator–semiconductor (MIS) structured sample and a damascene Cu interconnect sample. Compared to a direct-current (DC) stress condition, the time to failure (TTF) obtained in the alternating-polarity test was twice as high in the damascene structure and more than five times greater in the MIS structure. This increased lifetime under alternating polarity over that in DC stress resulted from recovery due to the backward migration of Cu ions during the reverse-bias stress. However, the TTF increase was saturated due to the hindrance of backward Cu migration by diffusional flux during reverse-bias stress. The longest TTFs were obtained with the largest-polarity alternating frequency and this effect was analyzed through a one-dimensional finite-difference method simulation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.