Abstract
The best estimate plus uncertainty (BEPU) is an advanced method which has been widely adopted in nuclear power plant safety analysis. In order to investigate the transient behaviors of the pressurized water reactor CPR1000 during the cold leg small break loss of coolant accident (SBLOCA) at different break sizes, BEPU analysis of the SBLOCA was carried out in this study, and the sizes of the break were 0.2%, 0.4%, 0.6%, 0.8% and 1.0% of the cross-sectional area of the cold leg, respectively. The minimum collapsed level (MCL) in the active core section was determined to be the figure of merit (FOM). The base case calculations, uncertainty propagation calculations and sensitivity analysis calculations were performed with the NUSOL-SYS code. Based on the results, the transient behaviors were analyzed, the lower 95/95 tolerance limits of the MCL at different break sizes were quantified, and the important input parameters were determined.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.