Abstract

The corrosion of a wire rope reduces its life expectancy. In this study, repeated bending tests were conducted using a bending fatigue tester by changing the tensile load and corrosion time of wire ropes, which were the same type as those used in elevators. The number of broken wires was studied, and a tensile test was conducted for cases in which the fracture was severe. The effect of corrosion fatigue on life expectancy was considered by comparing fracture strength values and observing fracture surfaces. The results indicate that an increase in accumulated corrosion fatigue, a greater tensile load, and repeated bending cycles may yield a rapid decrease in fracture strength and an increase in the number of broken wires. Therefore, it is concluded that corrosion fatigue is an important factor that decreases the life expectancy of wire rope.