Abstract

Only a limited number of experimental and analytical reports exist concerning large capacity, eight-bolt, extended endplate connections. This paper describes the structural properties, both stiffness and strength, of an extended endplate connected to a column flange, with no stiffeners in either tension or compression region, using eight high strength fully and partially prestressed bolts. The case studies considered in this paper offer greater insight into the significance of endplate and column flange interaction and bolt positioning; besides the displacement and stress distributions, the prying phenomenon is also addressed. The methodology is based on a finite element modeling developed previously for the standard four-bolt array. ANSYS, version 4.4, a large-scale general purpose code is selected for equivalent three-dimensional (3D) analysis. The end-plate, beam and column flanges and web are represented as plate elements. Each bolt shank is modeled using six spar elements. 3D interface elements are used to model the boundary between column flange and back of the end-plate that may make or break contact.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.