Abstract

Classical bearing capacity expressions can not afford variant engineering requests, since they were deducted under hypotheses of strip footing on homogeneous soil. An often met case was taken into account that circular footing on two-layered ground, which has firm crust and weak subgrade. Weighted method and layered method were used in capacity deduction, respectively. The former counts layered soils as single layer of weighted structure and material parameters. But it is restricted to conditions with close strength to each layer. The latter is preferred in engineering calculation, which regards the whole bearing capacity as subgrade’s capacity under the influence of the upper layer. Thus the issue is transformed to K. Terzaghi model plus stress reduction and dispersion effects. At last, the expressions gained from both methods and finite element analysis (FEA) were used in an example calculation, respectively. It approves layered calculating method and suggests the corresponding security coefficient based on elastoplastic FEA results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.