In this paper, system identification is carried out for a 20 kWh battery using real-world measurements data. State-of-charge (SOC) and the open-circuit voltage (V oc ) relationship will be obtained using least square estimation (LSE) non-linear regression. In addition, how to estimate SOC using current measurements and how to estimate the equivalent circuit's RC parameters are carried out using autoregressive exogenous (ARX) models. The respective ARX models are first derived. Estimation of the ARX coefficients is then carried out. Finally, parameter recovery is conducted to find out parameters with physical meanings, e.g., RC values. With the identified Voc and SOC relationship and RC parameters, we built a simulation model in MATLAB/Simpowersystems. With the measured current data from the real-world as the input, the simulation model gives the terminal DC voltage as the output. This output is compared with the real-world DC voltage measurements data and the matching degree is satisfactory.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.