Abstract

Ex vivo confocal microscopy (CM) works under two modes, fluorescence and reflectance, allowing the visualization of different structures. Fluorescence CM (FCM) requires a contrast agent and has been used for the analysis of basal cell carcinomas (BCCs) during Mohs surgery. Conversely, reflectance CM (RCM) is mostly used for invivo diagnosis of equivocal skin tumours. Recently, a new, faster exvivo confocal microscope has been developed which simultaneously uses both lasers (fusion mode). To describe the BCC features identified on reflectance, fluorescence and fusion modes using this novel device. To determine the best mode to identify characteristic BCC features. To develop a new staining protocol to improve the visualization of BCC under the different modes. From September 2016 to June 2017, we prospectively included consecutive BCCs which were excised using Mohs surgery in our department. The lesions were evaluated using exvivo CM after routine Mohs surgery. The specimens were first stained with acridine orange and then stained using both acetic acid and acridine orange. We included 78 BCCs (35 infiltrative, 25 nodular, 12 micronodular, 6 superficial). Most features were better visualized with the fusion mode using the double staining. We also identified new CM exvivo features, dendritic and plump cells, which have not been reported previously. Our results suggest that nuclei characteristics are better visualized in FCM but cytoplasm and surrounding stroma are better visualized in RCM. Thus, the simultaneous evaluation of reflectance and fluorescence seems to be beneficial due to its complementary effect. What's already known about this topic? Ex vivo fluorescent confocal microscopy (FCM) is an imaging technique that allows histopathological analysis of fresh tissue. FCM is faster - at least one-third of the time - than conventional methods. FCM has a sensitivity of 88% and a specificity of 99% in detecting basal cell carcinomas (BCCs). What does this study add? Reflectance and fluorescence modes can be used simultaneously in a new exvivo CM device. Each mode complements the other, resulting in an increase in the detection of BCC features in fusion mode. A combined staining using acetic acid and acridine orange enhances the visualization of tumour and stroma without damaging the tissue for further histopathological analysis.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call