Abstract

In the present study, a quasi-static compression test and impact test are carried out on a Polycarbonate plate with thickness of 2.66 mm and an effective diameter of 205 mm. The impact test is carried out on a pneumatic gun using a hardened truncated cone projectile of mass 25.8 g at different velocities. On the other hand, a servo mechanical universal testing machine with a 50 kN capacity is used to carry out the quasi-static compression test at a speed of 2 mm/min adopting an indenter of truncated nose shape. The Dynamic Enhancement Factor, or DEF, is computed as the ratio of quasi-static perforation energy to impact perforation energy. The measured DEF in the present study is compared with previously published results for metal and polycarbonate. Also local deformation of the plate after perforation is compared for both quasi-static test and dynamic test.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.