Abstract

To evaluate the effect of wall surface wettability on the characteristics of upward gas-liquid annular two-phase flow in a vertical pipe, an experimental study was performed using two test pipes: an acrylic pipe and a FEP pipe. Measured contact angles on the acrylic and FEP pipe surfaces were 60° and 80°, respectively. Basic flow characteristics such as liquid film thickness and liquid entrainment ratio were respectively measured by a laser focus displacement meter and a suction method. At relatively high gas flow rate and low liquid flow rate conditions, a reduction of the surface wettability by the FEP pipe enhanced the interfacial waves on liquid film, and caused an increase in the liquid entrainment ratio and a decrease in the liquid film thickness.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.