AbstractThe effect of back mixing of either phase in an extraction column, which decreases the extraction efficiency, is analyzed theoretically by means of an idealized diffusion model that can be characterized by four dimensionless parameters: a Peclet number of each phase, a mass transfer number, and the usual extraction factor. Calculations for a wide range of these parameters were performed on a digital computer.The principal results, presented in a table, will be useful in the design and scale up of extraction columns and in the interpretation of experimental results from extractors and from some reactors in which a first‐order reaction occurs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.