Abstract

The effects of liquid and gas velocities, liquid viscosity and surface tension, particle size and column diameter on the axial dispersion coefficients (D Z) of liquid phase in three-phase fluidized beds have been determined in two large (0.254 and 0.376 m-I.D.) columns. Tap water, carboxymethyl cellulose (CMC), Triton X-100 and ethanol aqueous solutions were used as the liquid phase; air as the gas phase and four different sizes of glass beads as the solid phase. The coefficient increases with increasing gas and liquid velocities in three phase fluidized beds. Whereas, the effects of liquid surface tension and liquid viscosity on D Z are found to be small. The axial dispersion coefficient decreases with increasing particle size and it sharply increases with increasing column size. The axial dispersion coefficients in terms of the Peclet number in the bubble coalescing and disintegrating regimes in three phase fluidized beds have been correlated based on the isotropic turbulence theory.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.