AbstractSeveral codes and design guidelines are now available for the design of concrete structures reinforced with fiber-reinforced polymer (FRP) bars under flexural and shear loads. Yet, because of a lack of research, North American codes and design guidelines do not recommend using FRP bars as longitudinal reinforcement in columns to resist compressive stresses. This paper reports on 12 full-scale circular reinforced concrete (RC) columns that were tested under concentric axial loads. The columns were reinforced with longitudinal glass FRP (GFRP) bars and newly developed GFRP spirals. The 300-mm diameter columns were designed according to code requirements. The test parameters included reinforcement type (GFRP versus steel); longitudinal FRP reinforcement ratio; and the volumetric ratios, diameters, and spacing of spiral reinforcement. The test results indicated that the GFRP and steel RC columns behaved in a similar manner. The average load carried by the longitudinal GFRP bars ranged between 5% and 1...