Abstract

Deep learning-based methods for cardiac MR segmentation have achieved state-of-the-art results. However, these methods can generate incorrect segmentation results which can lead to wrong clinical decisions in the downstream tasks. Automatic and accurate analysis of downstream tasks, such as myocardial tissue characterization, is highly dependent on the quality of the segmentation results. Therefore, it is of paramount importance to use quality control methods to detect the failed segmentations before further analysis. In this work, we propose a fully automatic uncertainty-based quality control framework for T1 mapping and extracellular volume (ECV) analysis. The framework consists of three parts. The first one focuses on segmentation of cardiac structures from a native and post-contrast T1 mapping dataset (n=295) using a Bayesian Swin transformer-based U-Net. In the second part, we propose a novel uncertainty-based quality control (QC) to detect inaccurate segmentation results. The QC method utilizes image-level uncertainty features as input to a random forest-based classifier/regressor to determine the quality of the segmentation outputs. The experimental results from four different types of segmentation results show that the proposed QC method achieves a mean area under the ROC curve (AUC) of 0.927 on binary classification and a mean absolute error (MAE) of 0.021 on Dice score regression, significantly outperforming other state-of-the-art uncertainty based QC methods. The performance gap is notably higher in predicting the segmentation quality from poor-performing models which shows the robustness of our method in detecting failed segmentations. After the inaccurate segmentation results are detected and rejected by the QC method, in the third part, T1 mapping and ECV values are computed automatically to characterize the myocardial tissues of healthy and cardiac pathological cases. The native myocardial T1 and ECV values computed from automatic and manual segmentations show an excellent agreement yielding Pearson coefficients of 0.990 and 0.975 (on the combined validation and test sets), respectively. From the results, we observe that the automatically computed myocardial T1 and ECV values have the ability to characterize myocardial tissues of healthy and cardiac diseases like myocardial infarction, amyloidosis, Tako-Tsubo syndrome, dilated cardiomyopathy, and hypertrophic cardiomyopathy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.