Abstract

AbstractWe propose the techniques for automatic processing of measurement results in the context of golden (typical) device selection and noise figure measurement. These techniques are for golden (typical) device selection and noise figure measurement processing. Automation of measurement result processing and microwave element modeling speeds up a modeling routine and decreases the risk of possible errors. The techniques are validated through modeling of 0.15 μm GaAs pHEMTs with 4 × 40 μm and 4 × 75 μm total gate widths. Two test amplifiers were designed using the developed models. The amplifier modeling results agree well with measurements which confirms the validity of the proposed techniques. The proposed algorithm is potentially applicable to other circuit types (switches, digital, power amplifiers, mixers, oscillators, etc.) but may require different settings in those cases. However, in the presented work, we validated the algorithm for the linear and low-noise amplifiers only.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.