Abstract

Automatic Gestational Age (GA) estimation based on the Crown Rump Length (CRL) measurement is the preferred solution to overcome the challenges while using the last menstrual period (LMP) to date pregnancies. However, GA estimation based on CRL requires accurate placement of calipers on the fetal crown and rump which is not always a straightforward task, especially for an inexperienced sonographer. This paper proposes an accurate GA estimation method from fetal CRL images during the first trimester scan. The method addresses this problem by segmenting the fetus using a binary and multi-class U-Net. The fetal segmentation is used to compute the CRL. This is then followed by an estimation of GA from the automatic CRL measurement based of clinical information. The results from the multi-class segmentation achieves a more accurate precision, recall, Dice, and Jaccard. This has also led to a more accurate CRL measurement and hence more robust GA estimation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.