We present what we believe to be the first automatic alignment of a synchrotron beamline by the Hartmann technique. Experiments were performed, in the soft-x-ray range (E=3 keV, lambda=0.414 nm), by using a four-actuator Kirkpatrick-Baez (KB) active optic. A system imaging the KB focal spot and a soft-x-ray Hartmann wavefront sensor were used alternatively to control the KB optic. The beam corrected with the help of the imaging system was used to calibrate the wavefront sensor. With both closed loops, we focused the beam into a 6.8 microm x 9 microm FWHM focal spot.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.