Abstract

BackgroundA new software version of VolparaDensity (Volpara Algorithm version 1.5.1) is capable of calculating volumetric breast density (VBD) using either full-field digital mammography (FFDM) or digital breast tomosynthesis (DBT) images. In this preliminary study, we evaluated the feasibility and consistency of this new automated software.FindingsRaw data from both DBT and FFDM were acquired from women breast cancer screening at our institution between April and August 2015 using. The DBT and FFDM images obtained under a single compression were collected and VBD was measured using fully automated software. A paired t test was used to analyze differences in the VBD calculated from paired FFDM and DBT images. The correlation coefficient (R value) was calculated and p < 0.05 was considered significant. Dualmodality images were acquired in 160 women; VBD data were available for all but one. There was a significant difference in the VBD of individual breasts calculated from DBT and FFDM and when data were compared per case (<0.001 and p = 0.006, respectively). There were very good to excellent correlations between data from FFDM and from DBT (R = 0.78, p < 0.0001; per breast, R = 0.89, p < 0.0001, per case, R = 0.91, p < 0.0001).ConclusionsVBD from DBT was well correlated to that from FFDM, though significant differences were observed between the two.

Highlights

  • A new software version of VolparaDensity (Volpara Algorithm version 1.5.1) is capable of calculating volumetric breast density (VBD) using either full-field digital mammography (FFDM) or digital breast tomosynthesis (DBT) images

  • Previous investigations have demonstrated that DBT plus full-field digital mammography (FFDM) led to an increase in breast cancer detection rates while decreasing false-positive rates, compared with FFDM alone (Skaane et al 2013a, b; Ciatto et al 2013; Rafferty et al 2013)

  • Where the VBD measurement was available for both the mediolateral oblique (MLO) and CC views, the VBD of each breast was taken as the mean of the two views

Read more

Summary

Introduction

A new software version of VolparaDensity (Volpara Algorithm version 1.5.1) is capable of calculating volumetric breast density (VBD) using either full-field digital mammography (FFDM) or digital breast tomosynthesis (DBT) images. In this preliminary study, we evaluated the feasibility and consistency of this new automated software. Digital breast tomosynthesis (DBT) is a limited angle computed tomography technique in which sequential tomographic images through the breast can be reconstructed from projection images obtained at various angles. Studies have confirmed a strong correlation between VBD, calculated from mammography, and breast cancer risk (Eng et al 2014; Brand et al 2014; Trinh et al 2015; Schetter et al 2014)

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.