Abstract
An automated analytical procedure is described for the parallel determination of l-3,4-dihydroxyphenylalanine (levodopa, l-dopa, LD) and the analogous hydrazine compound carbidopa (CD) in dog plasma by ion-pair high-performance liquid chromatography with electrochemical detection (HPLC-ED). After deproteinization of the plasma samples with perchloric acid the catecholamines were extracted from the supernatant by adsorption on a small column filled with alumina. The extraction and redissolution were automatically performed in a flow injection analysis unit (FIA) coupled to the HPLC system. The performance of the whole system was tested on dog plasma samples including specimens taken after oral administration of the anti-Parkinsonism drug Duellin ®, which is a combination tablet of levodopa and carbidopa.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Chromatography B: Biomedical Sciences and Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.