Two-shaft rotary lobe pumps are often used for pumping suspensions with coarse matter, i.e in liquid manure, biogas and sewage treatment plants. Pump characteristics change considerably with increasing wear. Based on a mathematical model for wear-caused internal leakage, a new calculation programme for Computer Aided Pump Selection was developed, which combined with the well known programme for calculating pressure drop in pipes, makes it possible for the user to design a complex agricultural pumping system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.