Abstract

Due to the anatomic complexity of the head and neck and variable proximity between laboratory and operating room (OR), effective communication during frozen section analysis (FSA) between surgeons and pathologists is challenging. This proof-of-concept study investigates an augmented reality (AR) protocol that allows pathologists to virtually join the OR from the laboratory. Head and neck cancer specimens were scanned ex vivo using a 3-dimensional scanner and uploaded into an AR platform. Eight head and neck specimens were discussed by surgeons and pathologists in an AR environment. AR-guided intraoperative consultation was used for specimen orientation and discussion of FSA margin sampling sites. One patient had positive initial margins on FSA andwas re-resected to negative final margins. AR-guided FSA is possible and allows pathologists to join the operating from any location for intraoperative discussion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.