Abstract
Hemolytic transfusion reactions are often the result of failure to follow established identification and monitoring procedures. To measure the frequencies with which health care workers completed specific transfusion procedures required for laboratory and blood bank accreditation. In 2 separate studies, participants in the College of American Pathologists Q-Probes laboratory quality improvement program audited nonemergent red blood cell transfusions prospectively and completed questionnaires profiling their institutions' transfusion policies. A total of 660 institutions, predominantly in the United States, at which transfusion medicine services are provided. The percentages of transfusions for which participants completed 4 specific components of patient and blood unit identifications, and for which participants monitored vital signs at 3 specific intervals during transfusions. In the first study, all components of patient identification procedures were performed in 62.3%, and all required patient vital sign monitoring was performed in 81.6% of 12 448 transfusions audited. The median frequencies with which institutions participating in the first study performed all patient identification and monitoring procedures were 69.0% and 90.2%, respectively. In the second study, all components of patient identification were performed in 25.4% and all patient vital sign monitoring was performed in 88.3% of 4046 transfusions audited. The median frequencies with which institutions participating in the second study performed all patient identification and monitoring procedures were 10.0% and 95.0%, respectively. Individual practices and/or institutional policies associated with greater frequencies of patient identification and/or vital sign monitoring included transporting units of blood directly to patient bedsides, having no more than 1 individual handle blood units in route, checking unit labels against physicians' orders, having patients wear identification tags (wristbands), reading identification information aloud when 2 or more transfusionists participated, using written checklists to guide the administration of blood, instructing health care personnel in transfusion practices, and routinely auditing the administration of transfusions. In many hospitals, the functions of identification and vital sign monitoring of patients receiving blood transfusions do not meet laboratory and blood bank accreditation standards. Differences in hospital transfusion policies influence how well health care workers comply with standard practices. We would expect that efforts designed to perfect transfusion policies might also improve performance in those hospitals in which practice compliance is substandard.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.