Abstract

To compare virtual unenhanced (VUE) attenuation values and their agreement with true unenhanced (TUE) images in patients who underwent dual-layerdetector-based dual-energy computed tomography (dlDECT) with single- vs. split-bolus contrast media protocol. In this HIPAA-compliant, IRB-approved retrospective analysis, a total of 105 patients who underwent nephrographic phase (NP) dlDECT between 07/2018 and 11/2019 were included: 55 patients received single bolus and 50 patients split-bolus examinations. Both scan protocols comprised a TUE and 120-kVp NP acquisition from which VUE images were reconstructed. A radiologist performed ROI-based attenuation measurements of liver parenchyma, main portal vein, aorta, spleen, renal parenchyma, and pelvis on TUE andVUE images. Agreement between TUE and VUE images was determined and compared for both protocols and each anatomic region. VUE attenuation was significantly higher than TUE attenuation in both cohorts in the liver, portal vein, spleen, and renal parenchyma (p < 0.05), while it was similar in the abdominal aorta in both cohorts (p = 0.05, 0.7522, respectively). VUE attenuation was significantly higher than TUE attenuation in the renal pelvis of the split-bolus cohort (p < 0.05). When comparing VUE images between single- and split-bolus protocols, the renal parenchyma yielded a significantly higher VUE attenuation in the single-bolus cohort (single bolus: 38.8 ± 3.3 HU vs. split bolus: 36.8 ± 3.6 HU; p < 0.05), whereas the split-bolus cohort revealed markedlyhigher VUE attenuation in the renal pelvis (single bolus: 2.3 ± 10.8 HU vs. split bolus: 92.3 ± 76.8; p < 0.05). Mean intra-patient differences between TUE and VUE images were comparable between single- and split-bolus cohorts (p-range 0.09-0.35) except for the renal parenchyma and pelvis: in the first, the single-bolus cohort yielded a higher VUE attenuation, while in the second, attenuation was significantly higher in the split-bolus cohort (p < 0.05). VUE attenuation overestimated TUE attenuation and differed between split- and single-bolus protocols for the renal parenchyma and pelvis, while all other tissues showed comparable VUE attenuation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.