Abstract

An elbow-shaped surge tank is proposed to suppress the pressure pulsations. The transfer matrix method was developed and the mathematical model was established to predict the distribution of pressure pulsations in the piping system (on which a surge tank was already installed) with an elbow-shaped surge tank. Simulation work of the whole piping system was performed. The results show that the elbow-shaped surge tank has good performance to attenuate the pressure pulsations. The frequency analysis shows that the amplitude for the first pulsation frequency is attenuated to a low level. The impulse response was analyzed to examine the efficiency of suppressing pulsations by using the suppressor. The theoretical analysis showed that there exists the optimal suppression performance when setting the distance between the elbow-shaped surge tank and the existing one. Meanwhile, modifying the ratio of length to diameter with a fixed surge volume could also impact the pressure pulsations. The analysis results can be used as a reference in designing and installing the elbow-shaped surge tank.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call