Abstract

Background and Objectives: Increased mortality in epilepsy due to infections (other than pneumonia) has been demonstrated. Small case series of people on antiepileptic drugs (AEDs) have described hypogammaglobulinaemia, which may predispose to infections. It is unclear whether hypogammaglobulinaemia is more frequent in people on AEDs, what AEDs it is associated with, or what clinical impact it has. In this population-based study, we aimed to determine whether AEDs were associated with hypogammaglobulinaemia, which AEDs were associated, and whether the associations may be causal. Methods: We conducted an unmatched case-control study using data linkage of routinely collected biochemistry, prescribing, and morbidity datasets in North-East Scotland from 2009–2021. Cases were participants with immunoglobulin levels less than the reference range. Controls were those with normal/high immunoglobulin levels. Logistic regression was used to investigate associations between AED exposure and any hypogammaglobulinaemia, adjusting for age, sex, and comorbidity. We also analysed low IgA, IgM, and IgG separately. We analysed “any AED” exposure and common individual drugs separately. Cumulative exposure data were used to determine whether an exposure-response relationship was present. Results: 18,666 cases and 127,157 controls were identified. Use of any AED was associated with increased risk of hypogammaglobulinaemia (adjusted odds ratio [aOR] 1.20 [95% CI: 1.15–1.25]). Phenytoin use was strongly associated with low IgA (aOR 5.90 [95% CI: 3.04, 10.43]). Carbamazepine and lamotrigine were also associated with low IgA. Apart from topiramate, which was associated with a non-significant decrease in odds of hypogammaglobulinaemia, there was a consistent increase in odds of hypogammaglobulinaemia across most AEDs studied. Panhypogammaglobulinaemia was associated with any AED use, carbamazepine, lamotrigine, gabapentin, and multiple AED use. There was evidence of an exposure-response relationship between any AED use and any hypogammaglobulinaemia, low IgA, and low IgG. Carbamazepine and probably lamotrigine also had an exposure-response relationship with any hypogammaglobulinaemia. Discussion: AEDs may increase hypogammaglobulinaemia risk. Specific classes of immunoglobulins are differentially affected, and the exposure-response analysis suggests this may be causal. Further work should investigate the clinical impact of these findings. Clinicians should check immunoglobulin levels if unusual or recurrent infections occur in patients treated with AEDs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.