Abstract
Resting heart rate (HR) and routine physical activity are associated with cardiorespiratory fitness levels. Commercial smartwatches permit remote HR monitoring and step count recording in real-world settings over long periods of time, but the relationship between smartwatch-measured HR and daily steps to cardiorespiratory fitness remains incompletely characterized in the community. This study aimed to examine the association of nonactive HR and daily steps measured by a smartwatch with a multidimensional fitness assessment via cardiopulmonary exercise testing (CPET) among participants in the electronic Framingham Heart Study. Electronic Framingham Heart Study participants were enrolled in a research examination (2016-2019) and provided with a study smartwatch that collected longitudinal HR and physical activity data for up to 3 years. At the same examination, the participants underwent CPET on a cycle ergometer. Multivariable linear models were used to test the association of CPET indices with nonactive HR and daily steps from the smartwatch. We included 662 participants (mean age 53, SD 9 years; n=391, 59% women, n=599, 91% White; mean nonactive HR 73, SD 6 beats per minute) with a median of 1836 (IQR 889-3559) HR records and a median of 128 (IQR 65-227) watch-wearing days for each individual. In multivariable-adjusted models, lower nonactive HR and higher daily steps were associated with higher peak oxygen uptake (VO2), % predicted peak VO2, and VO2 at the ventilatory anaerobic threshold, with false discovery rate (FDR)-adjusted P values <.001 for all. Reductions of 2.4 beats per minute in nonactive HR, or increases of nearly 1000 daily steps, corresponded to a 1.3 mL/kg/min higher peak VO2. In addition, ventilatory efficiency (VE/VCO2; FDR-adjusted P=.009), % predicted maximum HR (FDR-adjusted P<.001), and systolic blood pressure-to-workload slope (FDR-adjusted P=.01) were associated with nonactive HR but not associated with daily steps. Our findings suggest that smartwatch-based assessments are associated with a broad array of cardiorespiratory fitness responses in the community, including measures of global fitness (peak VO2), ventilatory efficiency, and blood pressure response to exercise. Metrics captured by wearable devices offer a valuable opportunity to use extensive data on health factors and behaviors to provide a window into individual cardiovascular fitness levels.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.