Abstract

Fresh frozen plasma (FFP) transfusion is used to manage coagulopathy and bleeding in cardiac surgery patients despite uncertainty about its safety and effectiveness. We performed a propensity score matched analysis of the Australian and New Zealand Society of Cardiac and Thoracic Surgeons National Cardiac Surgery Database including patients from 39 centres from 2005 to 2018. We investigated the association of perioperative FFP transfusion with mortality and other clinical outcomes. Of 119,138 eligible patients, we successfully matched 13,131 FFP recipients with 13,131 controls. FFP transfusion was associated with 30-day mortality (odds ratio (OR), 1.41; 99% CI, 1.17-1.71; p < .0001), but not with long-term mortality (hazard ratio (HR), 0.92; 99% CI, 0.85-1.00; p = .007, Holm-Bonferroni α = 0.0004). FFP was also associated with return to theatre for bleeding (OR, 1.97; 99% CI, 1.66-2.34; p < .0001), prolonged intubation (OR, 1.15; 99% CI, 1.05-1.26; p < .0001) and increased chest tube drainage (Mean difference (MD) in mL, 131; 99% CI, 120-141; p < .0001). It was also associated with reduced postoperative creatinine levels (MD in g/L, -6.33; 99% CI, -10.28 to -2.38; p < .0001). In a multicentre, propensity score matched analysis, perioperative FFP transfusion was associated with increased 30-day mortality and had variable associations with secondary clinical outcomes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call