Abstract
Continuous glucose monitoring (CGM) devices have demonstrated efficacy in adults and more recently in youths and older adults with type 1 diabetes. In adults with type 1 diabetes, the use of real-time CGM compared with intermittently scanned CGM was associated with improved glycemic control, but there are limited data available for youths. To assess real-world data on achievement of time in range clinical targets associated with different treatment modalities in youths with type 1 diabetes. This multinational cohort study included children, adolescents, and young adults younger than 21 years (hereinafter referred to collectively as youths) with type 1 diabetes for a duration of at least 6 months who provided CGM data between January 1, 2016, and December 31, 2021. Participants were enrolled from the international Better Control in Pediatric and Adolescent Diabetes: Working to Create Centers of Reference (SWEET) registry. Data from 21 countries were included. Participants were divided into 4 treatment modalities: intermittently scanned CGM with or without insulin pump use and real-time CGM with or without insulin pump use. Type 1 diabetes and the use of CGM with or without an insulin pump. Proportion of individuals in each treatment modality group achieving recommended CGM clinical targets. Among the 5219 participants (2714 [52.0%] male; median age, 14.4 [IQR, 11.2-17.1] years), median duration of diabetes was 5.2 (IQR, 2.7-8.7) years and median hemoglobin A1c level was 7.4% (IQR, 6.8%-8.0%). Treatment modality was associated with the proportion of individuals achieving recommended clinical targets. Adjusted for sex, age, diabetes duration, and body mass index standard deviation score, the proportion achieving the recommended greater than 70% time in range target was highest with real-time CGM plus insulin pump use (36.2% [95% CI, 33.9%-38.4%]), followed by real-time CGM plus injection use (20.9% [95% CI, 18.0%-24.1%]), intermittently scanned CGM plus injection use (12.5% [95% CI, 10.7%-14.4%]), and intermittently scanned CGM plus insulin pump use (11.3% [95% CI, 9.2%-13.8%]) (P < .001). Similar trends were observed for less than 25% time above (real-time CGM plus insulin pump, 32.5% [95% CI, 30.4%-34.7%]; intermittently scanned CGM plus insulin pump, 12.8% [95% CI, 10.6%-15.4%]; P < .001) and less than 4% time below range target (real-time CGM plus insulin pump, 73.1% [95% CI, 71.1%-75.0%]; intermittently scanned CGM plus insulin pump, 47.6% [95% CI, 44.1%-51.1%]; P < .001). Adjusted time in range was highest among real-time CGM plus insulin pump users (64.7% [95% CI, 62.6%-66.7%]). Treatment modality was associated with the proportion of participants experiencing severe hypoglycemia and diabetic ketoacidosis events. In this multinational cohort study of youths with type 1 diabetes, concurrent use of real-time CGM and an insulin pump was associated with increased probability of achieving recommended clinical targets and time in range target as well as lower probability of severe adverse events compared with other treatment modalities.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.