Abstract

Purpose Iris biological features such as surface features and profile characteristics reflected the development of iris stroma and microvessels. Iris vessels and microcirculation are still lack of effective detection methods, and we can directly observe only the iris surface biological characteristics. This cross-sectional study evaluated the association between iris surface biological features and corneal biomechanics in young adults with myopia. Methods We recruited 152 patients with myopia aged ≥18 years, from the Eye Hospital of Wenzhou Medical University, who had complete Corneal Visualization Scheimpflug Technology (Corvis ST) data and graded iris surface features. Iris surface features included crypts, furrows, and color measured from digital slit lamp images. The biomechanical properties of the cornea were assessed using Corvis ST. Only 1 eye of each participant was randomly selected for analysis. Associations between the iris surface features and corneal biomechanics were analyzed using linear regression models. The grade of iris crypts, furrows, and color and corneal biomechanical parameters measured with Corvis ST was the main outcome measures. Results The iris crypts were significantly associated with deflection amplitude at the first applanation (A1 DLA, β = 0.001, P = 0.013), A1 delta arc length (A1 dArcL) (β = −0.001, P = 0.01), maximum delta arc length (dArcLM) (β = −0.004, P = 0.03), and stiffness at the first applanation (SP-A1) (β = −2.092, P = 0.016). The iris furrows were only associated with integrated radius (β = −0.212, P = 0.025). Iris color was found not related with corneal biomechanical parameters measured via Corvis ST. Conclusions Iris surface features were associated with corneal biomechanical properties in myopic eyes; more iris crypts were associated with lower corneal stiffness while more extensive furrows were related with higher corneal stiffness. Iris crypts and furrows may provide useful information on corneal biomechanical properties in myopic eyes.

Highlights

  • Cornea is an important part of the refractive system of the human eye, and its refractive power accounts for more than 3/4 of the whole refractive system

  • Approval was obtained from the Institutional Review Board (IRB) of Wenzhou Medical University (IRB approval number: 2020-128-K-113), and the study was conducted according to the tenets of the Declaration of Helsinki

  • Our study found that iris surface features are associated with corneal biomechanics

Read more

Summary

Introduction

Cornea is an important part of the refractive system of the human eye, and its refractive power accounts for more than 3/4 of the whole refractive system. Laser corneal refractive surgery can correct ametropia by cutting the corneal stroma to change the curvature of the anterior surface. Refractive surgery for myopia will reduce the number of central corneal lamellar and change the structure and biomechanical properties of cornea [1]. Different cutting methods and depths have different effects, which may affect the predictability of surgery and the occurrence of complications such as refractive regression and keratectasia [2, 3]. Sufficient evaluation of the corneal biomechanical properties has a strong guiding significance for the safety of refractive surgery

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call