Abstract
The IFMIF-like fusion neutron sources (FNSs) such as A-FNS and IFMIF-DONES have Li fire risks and the R&D activity for the Li fire risk reduction has been conducted under the IFMIF/EVEDA project. The objectives of this study are to experimentally elucidate humidity condition in airat which no Li fire ignites and the effect of the heat insulator on the Li fire ignition. The experimental set-up was designed and fabricated in order to perform Li fire experiments safely and systematically. Around 1 g of metallic Li samples were heated with and without the heat insulators as an experimental parameter of humidity in air. In this work, no ignition was observed under the less than 0.15 vol% humidity air. The heating experiments with the heat insulators clarified that the reaction between Li and the heat insulators causing Li fire ignition didn’t occur. In conclusion, the results of the present study suggest the conditions of less than 0.15 vol% humidity air and employing the heat insulator of alkaline earth silicate wool are useful for the Li target system of FNSs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.