Abstract

The tube to tubesheet joint in a heat exchanger is one of the most critical joint and it has to meet stringent requirements as it provides the main barrier between the tube side and shell side fluids of heat exchanger. This paper discusses the various kinds of tube to tubesheet joint in heat exchanger, joint configuration adopted in PFBR IHX, structural analysis of IHX, axial load distribution in tube rows and experimental verification in order to evaluate allowable strength of tube to tubesheet joint. In IHX, tubes in outer rows are under tension and maximum stresses are below the allowable stresses in the tubes. Detailed experimental investigations result shows that the rolled and welded joint is stronger than the basic strength of the tube material. However, the allowable tensile strength of the joint under mechanical loading considered is 0.95 times the allowable value for tubes as per ASME.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.