Abstract

The inclusion of baffles in a double pipe heat exchanger is becoming increasingly important as it improves the heat exchanger's performance. The CFD analysis is used in this paper to investigate the performance of double pipe heat exchangers with and without helical baffles on both shell tube sides. The 3-D CFD model was created in Solid Works, and the FloEFD software was used to analyze the conjugate heat transfer between the heat exchanger's tube and shell sides. Heat transfer characteristic like outlet temperature of shell and tube are investigated along with pressure drop on shell and tube side. Based on CFD results of double pipe heat exchanger with helical baffle on both shell side and tube side (Type 4) gives the better results than the other type of heat exchangers with an increased pressure drop than the others, results reveals that Type 4 outlet temperature of shell side is 8% higher and on tube side it is 5.5% higher, also pressure drop on shell side is 12% higher and on tube side it is 42% higher than the other types.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.